The cooling system is one of the most important systems in a ship's engine room. Main engines, auxiliary engines, air compressors, lubricating oil coolers and several other machinery units generate heat during operation. This heat must be continuously removed to keep the machinery within its recommended operating temperature range.

Modern merchant ships commonly use a central cooling system, which is divided into three interconnected circuits:

  • Seawater (SW) cooling circuit

  • Low-Temperature (LT) freshwater cooling circuit

  • High-Temperature (HT) freshwater cooling circuit

The LT cooler and HT cooler play different roles in this arrangement. The LT cooler transfers heat from the freshwater system to seawater, while the HT cooler transfers heat from the main engine's hot jacket water circuit to the cooler LT freshwater circuit.

Understanding these two coolers is important for marine engineers, particularly when dealing with high cooling-water temperatures, cooler choking, leakage, maintenance and engine-room troubleshooting.

This article explains the working principle of LT and HT coolers, the machinery connected to the LT system, common operational problems and practical points for MEO Class 4 examinations.


1. What Is an LT Cooler on a Ship?

An LT cooler (Low-Temperature Cooler) is a heat exchanger installed in the engine room's central cooling system. It removes heat from the closed-loop LT freshwater circuit by transferring it to seawater, which is discharged overboard.

It acts as the final heat sink for the central freshwater cooling system.

Instead of allowing seawater to circulate through individual machinery coolers, the central cooling arrangement uses treated freshwater to cool most engine-room machinery. The LT cooler then transfers the collected heat to seawater.

This arrangement reduces the exposure of machinery to seawater, helping prevent saltwater corrosion, scale formation and fouling inside individual coolers.


How Does an LT Cooler Work?

The working principle is based on heat transfer between two fluids at different temperatures.

  1. Seawater is drawn from the sea chest by the seawater cooling pump.

  2. It passes through the seawater side of the LT cooler.

  3. Hot LT freshwater passes through the other side of the cooler.

  4. Heat transfers from the warmer freshwater to the cooler seawater through the heat-transfer plates.

  5. The cooled LT freshwater returns to the engine-room cooling circuit.

  6. The warmed seawater is discharged overboard.

The two fluids remain separated by the cooler plates and should not mix during normal operation.


Main Components of an LT Cooler

Most modern central cooling systems use plate-type heat exchangers as LT coolers.

Their main components include:

Plate-type LT cooler used in a ship's central freshwater cooling system with main components labelled
  • Frame: Supports the complete cooler assembly.

  • Heat-transfer plates: Provide the surface through which heat is transferred.

  • Gaskets: Seal the passages and prevent mixing between the two fluids.

  • Tie bolts: Hold the plate pack together.

  • Inlet and outlet connections: Allow seawater and freshwater to enter and leave the cooler.

  • Pressure and temperature connections: Help monitor cooler performance.

Titanium plates are commonly used on the seawater side because of their resistance to seawater corrosion. The exact material depends on the cooler design and manufacturer.


2. Understanding the Three Cooling Circuits

To understand LT and HT coolers, it is necessary to understand how the central cooling system is arranged.

Marine engine room seawater and freshwater cooling circuits.

A. Seawater Cooling Circuit

The seawater circuit is an open circuit. It draws seawater from the sea through the sea chest and passes it through the central LT cooler.

After absorbing heat from the LT freshwater, the seawater is discharged overboard.

The seawater circuit generally consists of:

  • Sea chest

  • Sea chest strainer

  • Seawater cooling pump

  • LT cooler seawater side

  • Overboard discharge line

Since seawater contains salts, suspended particles and marine organisms, the seawater side is more susceptible to corrosion and fouling.


B. Low-Temperature (LT) Freshwater Circuit

The LT freshwater circuit is a closed circuit containing treated freshwater.

It receives heat from various machinery coolers throughout the engine room. This heated freshwater then passes through the LT cooler, where it transfers heat to seawater.

The cooled LT water is circulated back to the machinery.

In the reference arrangement discussed in this article, LT freshwater leaves the LT cooler at approximately 36°C. The actual operating temperature depends on the vessel's design, seawater temperature and machinery requirements.


C. High-Temperature (HT) Freshwater Circuit

The HT freshwater circuit is also a closed circuit. It is primarily responsible for cooling the main engine's:

  • Cylinder jackets

  • Cylinder heads or covers

  • Exhaust valve cages

The HT circuit maintains the main engine at its required operating temperature. The reference document gives a typical operating range of approximately 85°C to 95°C.

When the HT freshwater becomes too hot, heat is transferred to the LT freshwater circuit through the HT cooler.

A thermostatic three-way valve regulates the flow through the cooler and bypass line to maintain the required temperature.


3. What Machinery Is Cooled by the LT System?

One common misunderstanding is that every machine has a separate LT cooler.

In a central cooling arrangement, the LT freshwater line supplies individual heat exchangers fitted to different machinery. These coolers receive LT freshwater and transfer heat from the machinery's oil, air or other cooling medium.

The main machinery connected to the LT circuit includes:

Machinery

What the LT freshwater cools

Main engine

Lubricating oil cooler

Main engine

Scavenge air (charge air) cooler

Main engine

Piston cooling oil cooler, where fitted

Main engine

Fuel valve cooling module, where fitted

Main engine

HT jacket water through the HT cooler

Auxiliary engines

Lubricating oil cooler, charge air cooler and jacket water cooler

Air compressors

Intercoolers and cylinder cooling arrangements

Freshwater generator

Cooling arrangements, depending on design

Refrigeration and HVAC

Condensers and associated cooling equipment

Steering gear

Hydraulic oil cooler

Deck machinery

Hydraulic oil coolers, where connected

Purifiers

Associated oil cooling arrangements, where fitted

Stern tube

Stern tube lubricating oil cooler

The exact machinery connected to the LT circuit differs between vessels. Always refer to the ship's cooling-water diagram and machinery operating manual.


4. What Is an HT Cooler?

An HT cooler (High-Temperature Cooler) is a heat exchanger that removes heat from the main engine's HT jacket-water circuit by transferring it to the LT freshwater circuit.

Unlike the LT cooler, which transfers heat to seawater, the HT cooler works between two freshwater circuits.

The HT cooler is therefore a freshwater-to-freshwater heat exchanger.


How Does an HT Cooler Work?

The working principle is as follows:

  1. HT freshwater absorbs heat from the main engine cylinder jackets, cylinder heads and exhaust valve cages.

  2. The heated HT freshwater circulates through the HT cooling circuit.

  3. It passes through the HT cooler, where heat is transferred to the cooler LT freshwater.

  4. The HT freshwater temperature is reduced.

  5. The cooled HT water returns to the main engine.

  6. A thermostatic three-way valve regulates the amount of water passing through the cooler and the bypass line.

This arrangement allows the main engine to operate at a controlled temperature without exposing its jacket-water circuit directly to cold seawater.


Why Is the HT Cooling Circuit Kept Separate?

The HT circuit is maintained separately for two important reasons.

1. Prevention of Cold Corrosion

During combustion, sulphur in the fuel can contribute to the formation of acidic compounds. If the cylinder liner temperature becomes too low, acidic products may condense on the liner surface and contribute to corrosive wear.

Maintaining the correct jacket-water temperature helps reduce this risk.

2. Prevention of Thermal Shock

If cold seawater or low-temperature freshwater were circulated directly through the hot engine jacket, the sudden temperature difference could cause excessive thermal stresses.

The separate HT circuit helps maintain a more stable engine operating temperature and reduces the risk of thermal shock.


5. HT Cooler vs LT Cooler: Key Differences

Although both are heat exchangers, their functions and cooling mediums are different.

Feature

LT Cooler

HT Cooler

Full form

Low-Temperature Cooler

High-Temperature Cooler

Main function

Cools LT freshwater

Cools HT freshwater

Cooling medium

Seawater

LT freshwater

Fluid being cooled

LT freshwater

HT freshwater

Typical temperature reference

LT outlet around 36°C

HT circuit around 85–95°C

Main equipment served

Central LT cooling circuit

Main engine jacket-water circuit

Fouling risk

Higher on seawater side

Generally lower

Common plate material

Titanium for seawater service

Stainless steel or titanium, depending on design

Main concern

Seawater fouling, blockage and corrosion

Temperature control and freshwater-side condition

Remember: The LT cooler rejects heat to seawater. The HT cooler transfers heat to the LT freshwater circuit.


6. Why Are Two LT Coolers Fitted on Many Ships?

Many merchant ships have two LT coolers installed in parallel.

In a common arrangement, each cooler is designed to handle the full required cooling load independently. This is known as a 2 × 100% arrangement.

During normal operation:

  • One LT cooler remains in service.

  • The second LT cooler remains on standby.

  • If the running cooler becomes choked or develops a leak, the standby cooler can be brought into operation.

This provides redundancy and helps maintain cooling-water supply if one unit becomes unavailable.


Should Both LT Coolers Run When the Ship Is Sailing?

Not necessarily.

Under normal operating conditions, one correctly sized and clean LT cooler may be sufficient to handle the engine-room cooling load.

Running both coolers is not automatically better. Depending on the system design, dividing the seawater flow between two coolers may reduce the flow velocity through each cooler and encourage deposits to settle.

However, both coolers may be required in certain operating conditions, such as:

  • Very high seawater temperatures.

  • Increased cooling demand.

  • Partial fouling of the running cooler.

  • A vessel-specific cooling arrangement requiring multiple units in service.

Some vessels also use different arrangements, such as 2 × 50% or 3 × 50%.

Important: The actual number of coolers required during operation must always be confirmed from the vessel's machinery operating manual and the manufacturer's instructions.


What About HT Coolers?

Many vessels have a single HT cooler because it operates in a closed freshwater-to-freshwater arrangement and is generally less exposed to seawater fouling.

If two HT coolers are installed, the operating and standby arrangement depends on the vessel's design.


7. Why Do LT Coolers Get Choked?

When engineers say that an LT cooler is choked, they generally refer to a restriction in the seawater side of the cooler.

The LT freshwater circuit is a closed loop containing treated water, whereas the seawater circuit is exposed to mud, silt, marine growth and other debris.

Common Causes of LT Cooler Choking

1. Mud and Silt

When a ship operates in shallow waters, rivers or muddy ports, the seawater suction may draw in suspended mud and fine sand.

These particles can settle between the narrow passages of the cooler plates and restrict seawater flow.

2. Marine Growth

Marine organisms such as barnacles, mussels, algae and seaweed can enter through damaged or ineffective sea chest strainers and accumulate inside the cooler.

3. Shells and Other Debris

Broken shells, plastic waste and marine organisms may collect near the cooler inlet or block the flow passages.


8. Signs That an LT Cooler Is Choked

An LT cooler that is becoming blocked may show several operational symptoms.

1. Increase in Differential Pressure

Differential pressure (ΔP) is the pressure difference between the cooler inlet and outlet.

A significant increase above the normal operating range may indicate restricted seawater flow due to mud, marine growth or other deposits.

2. Rising LT Freshwater Temperature

If seawater flow is restricted, the cooler cannot remove heat effectively.

As a result, the LT freshwater outlet temperature may rise above its normal operating value.

3. Temperature Control Valve Fully Open

The LT temperature control valve may open further to increase cooling through the cooler.

If the valve reaches its full-open position and the temperature continues to rise, the cooler's heat-transfer capacity or another part of the cooling system should be investigated.

4. Higher Temperatures in Connected Machinery

Since the LT circuit supplies several machinery coolers, poor LT cooling performance can affect:

  • Main engine lubricating oil temperature.

  • Scavenge air temperature.

  • Auxiliary engine cooling performance.

  • Other machinery connected to the LT circuit.

A rising LT temperature should therefore not be ignored.


9. What Should Be Done When an LT Cooler Gets Choked?

The response depends on the severity of the blockage and the vessel's operating condition.

The following actions are described in the technical reference document.

1. Change Over to the Standby Cooler

If a standby LT cooler is available, change over according to the ship's operating procedure. This helps restore cooling capacity while the affected cooler is inspected.

2. Backwash the Cooler

Some systems allow seawater flow to be reversed temporarily to remove loose mud and debris.

Backwashing should only be carried out if the cooler and piping arrangement are designed for it and the manufacturer's procedure permits it.

3. Clean the Sea Chest Strainers

Inspect and clean the sea chest strainers and suction filters. This prevents additional debris from entering the cooling system.

4. Open and Clean the Cooler Plates

If backwashing does not restore normal performance, the cooler may need to be isolated, opened and cleaned.

For plate-type coolers, the plates should be inspected for deposits, corrosion, damage and gasket condition.

Cleaning pressure and methods must follow the manufacturer's instructions to avoid damaging the plates or gaskets.


10. How to Detect Leakage Between the Seawater and Freshwater Sides?

An LT cooler has separate seawater and freshwater passages. The two fluids must remain separated by the heat-transfer plates and gaskets.

If a plate develops a pinhole or a gasket becomes damaged, seawater and freshwater can leak into each other's circuits.

One important method of detecting this leakage is monitoring the freshwater expansion tank level and checking the freshwater chloride content.


Signs of Internal Leakage

1. Unusual Expansion Tank Level Changes

The expansion tank level can provide an early indication of leakage.

  • If freshwater pressure is higher than seawater pressure, freshwater may leak into the seawater side. This can cause the freshwater expansion tank level to fall.

  • If seawater pressure is higher than freshwater pressure, seawater may enter the freshwater circuit. This can cause the expansion tank level to rise.

The actual direction of leakage depends on the pressure difference across the damaged plate or gasket.

2. Increase in Chloride Content

A sudden increase in chloride concentration in the LT freshwater may indicate seawater contamination.

Chloride contamination can affect the protective chemicals in the cooling-water system and increase the risk of corrosion.

Routine freshwater testing is therefore important.

3. Reduction in Corrosion Inhibitor Concentration

If freshwater is leaking out and the system is being topped up, the concentration of corrosion inhibitors may reduce.

For this reason, cooling-water chemical test results should be monitored along with expansion tank levels.


How to Identify Which LT Cooler Is Leaking

If a vessel has two LT coolers installed in parallel, the faulty cooler can be identified through a systematic isolation procedure.

The reference document describes the following approach:

  1. Change over to one LT cooler and isolate the other cooler using its designated valves.

  2. Monitor the expansion tank level for any unusual change.

  3. Repeat the procedure with the other cooler if necessary.

  4. With the suspected cooler isolated and drained on the seawater side, check its seawater drain or vent for continuous freshwater leakage, following the approved procedure.

  5. Inspect the plates and gaskets for damage, pinholes or displacement.

If the source of leakage is still unclear, further inspection and testing may be required.

Safety note: Cooler isolation, depressurisation, draining and opening must be performed under the ship's approved procedure. Never open a pressurised cooler.


11. LT Cooler Maintenance and Inspection

Regular inspection helps maintain heat-transfer efficiency and prevents unexpected cooling-system problems.

Important maintenance checks include:

  • Monitor seawater inlet and outlet pressure.

  • Record cooler differential pressure.

  • Monitor LT freshwater inlet and outlet temperatures.

  • Inspect sea chest strainers and mud boxes.

  • Check for unusual changes in expansion tank levels.

  • Conduct routine freshwater chloride and inhibitor tests.

  • Inspect plates for deposits, damage and corrosion.

  • Check gaskets for wear, cracks, displacement or leakage.

  • Clean the cooler according to the manufacturer's instructions.

  • Ensure the standby cooler is ready for operation.

A good maintenance record also helps engineers identify gradual deterioration in cooler performance.


12. MEO Class 4: Important Questions and Answers on LT and HT Coolers


Q1. What is an LT cooler on a ship?

An LT cooler is a heat exchanger that transfers heat from the low-temperature freshwater cooling circuit to seawater. It is part of the ship's central cooling system.


Q2. What is an HT cooler?

An HT cooler is a heat exchanger that transfers heat from the main engine's high-temperature jacket-water circuit to the low-temperature freshwater circuit.


Q3. What is the main difference between an LT cooler and an HT cooler?

An LT cooler uses seawater to cool LT freshwater, whereas an HT cooler uses LT freshwater to cool HT freshwater.


Q4. Why is the main engine jacket-water circuit maintained at a higher temperature?

The HT circuit maintains the engine at its required operating temperature, helps reduce the risk of cold corrosion and avoids excessive thermal stresses caused by sudden cooling.


Q5. Which side of an LT cooler usually gets choked?

The seawater side is generally more susceptible to choking because it is exposed to mud, silt, marine growth and debris.


Q6. What are the symptoms of a choked LT cooler?

Common symptoms include increased differential pressure, rising LT freshwater temperature, reduced cooling performance and higher temperatures in machinery connected to the LT circuit.


Q7. How can seawater leakage into the LT freshwater system be detected?

A sudden rise in freshwater chloride content and an unexplained increase in expansion tank level may indicate seawater leakage into the freshwater circuit.


Q8. Why are two LT coolers installed on many merchant ships?

Two coolers provide redundancy. In a common 2 × 100% arrangement, one cooler operates while the other remains on standby.


Q9. Should both LT coolers run during normal sailing?

Not necessarily. One cooler may be sufficient during normal operation if it can handle the full cooling load. The actual arrangement depends on the vessel's design and operating conditions.


Q10. What is the purpose of a three-way thermostatic valve in the HT cooling system?

It regulates the flow of HT freshwater through the HT cooler and the bypass line to maintain the required jacket-water temperature.


Q11. Why is titanium commonly used in LT cooler plates?

Titanium offers good resistance to seawater corrosion, making it suitable for heat exchangers exposed to raw seawater.


Q12. What should an engineer check if the LT freshwater temperature keeps increasing?

The engineer should check cooler differential pressure, seawater flow, sea chest strainers, cooler condition, temperature-control valve operation, pump performance and other possible restrictions in the cooling circuit.


Conclusion

The LT and HT coolers are essential components of a ship's central cooling system. While the LT cooler removes heat from the freshwater circuit by transferring it to seawater, the HT cooler maintains the main engine's jacket-water temperature by transferring heat to the LT circuit.

For marine engineers, understanding the difference between these coolers is important not only for examinations but also for daily engine-room operations.

Regular monitoring of temperatures, differential pressure, expansion tank levels and freshwater quality can help identify problems before they affect machinery performance.

A well-maintained cooling system supports reliable engine operation, protects machinery from overheating and helps keep the vessel operating safely.