A Sewage Treatment Plant (STP) is a critical pollution-prevention system installed onboard ships to collect, treat and discharge sewage in accordance with applicable environmental regulations. Unlike a simple sewage holding tank, an STP uses a combination of mechanical, biological and disinfection processes to reduce organic matter, suspended solids and harmful microorganisms before the treated effluent is discharged or transferred ashore.

On many modern vessels, the STP is integrated with a vacuum toilet and sewage collection system. A typical arrangement consists of a vacuum collecting unit followed by a biological treatment plant incorporating aeration, settling and disinfection.


The IMO regulates sewage pollution from ships under MARPOL Annex IV, which covers sewage-treatment equipment, discharge requirements, surveys, certification and reception facilities.


What is a Sewage Treatment Plant?


A sewage treatment plant is a shipboard system designed to receive sewage and wastewater, biologically treat the organic matter, separate activated sludge, disinfect the clarified water and produce an effluent suitable for discharge where permitted.


In a conventional biological marine STP, the basic treatment sequence is:

Collection → Aeration → Biological treatment → Settling → Disinfection → Discharge


The biological stage is particularly important because microorganisms use oxygen to break down biodegradable organic matter.


A useful engineering representation is:

Organic matter + Oxygen + Microorganisms → Carbon dioxide + Water + Biomass


The exact process and equipment arrangement varies between manufacturers and approved plant designs.


What are the Main Sources of Sewage and Wastewater on a Ship?

Sewage generated onboard can originate from accommodation spaces, sanitary facilities, medical facilities and other domestic services.


Black Water

Black water is wastewater containing human excreta. Typical sources include:

  • Toilets

  • Urinals

  • Medical or hospital sanitary facilities


Grey Water

Grey water is wastewater generated from sources such as:

  • Showers

  • Wash basins

  • Baths

  • Laundry

  • Galley sinks

  • Dishwashing facilities


The precise streams connected to an STP depend on the ship's design and the approved sewage system.


IMO's MEPC.227(64) defines grey water separately from drainage originating from toilets, urinals and hospitals.


Why is a Sewage Treatment Plant Required on Ships?

Untreated sewage can introduce pathogens and organic pollutants into the marine environment. It can create health hazards, consume dissolved oxygen and produce visible pollution, particularly in coastal waters.


Therefore, international regulations control when and how sewage may be discharged from ships.

Under MARPOL Annex IV, ships within its scope must have an approved sewage treatment plant, an approved comminuting and disinfecting system, or an approved sewage holding tank, as applicable.


Basic Arrangement of a Marine Sewage Treatment System

A typical biological arrangement can be understood as:

Vacuum Toilets

↓

Vacuum Piping

↓

Sewage Collection Tank

↓

Transfer / Ejector System

↓

Aeration Chamber I

↓

Aeration Chamber II

↓

Settling Chamber

↓

Disinfection Chamber

↓

Discharge Pump

↓

Permitted Overboard Discharge / Shore Reception Facility

At the same time, settled activated sludge is returned to the biological treatment section.


What is a Vacuum Toilet System?

Vacuum toilets transport sewage using a pressure differential rather than relying entirely on gravity.


This arrangement offers several advantages for ships:

  • Low flushing-water consumption

  • Smaller sewage piping

  • Greater flexibility in pipe routing

  • Effective sewage transport over relatively long pipe runs

  • Suitability for ships where conventional gravity drainage is difficult


The vacuum system is particularly useful because ships have limited space and extensive accommodation areas distributed throughout the vessel.


What is the Vacuum Collecting Unit?


The vacuum collecting unit is responsible for collecting sewage and maintaining the vacuum required for the toilet system.


Its principal functions are:

  • Generating vacuum for vacuum toilets

  • Discharging sewage from the collection tank

  • Controlling automatic operation

  • Providing alarms and indications

  • Providing signals to the engine monitoring system


A typical arrangement includes:

  • Sewage atmospheric tank

  • Ejector

  • Ejector pump

  • Vacuum/pressure switch

  • Vacuum gauge

  • Motor-operated discharge valve

  • High-level switch

  • Low-level switch

  • Shut-off valve

  • Control panel


How is Vacuum Generated?

The vacuum is produced using an ejector and ejector pump.


The ejector pump circulates motive water through the ejector. The resulting flow creates a low-pressure region, producing vacuum in the connected vacuum piping.


The vacuum exists in the piping while the sewage collection tank itself remains at atmospheric pressure.

This is an important oral-examination point.


Is the sewage collection tank itself under vacuum?

Not necessarily. In this arrangement, the vacuum is maintained in the vacuum piping, while the sewage collection tank is atmospheric.


How Does the Vacuum Switch Control the Pump?

The vacuum switch automatically starts and stops the ejector pump according to the vacuum level.


In the LER3D arrangement described in the supplied material:

  • Pump starts at approximately –35 kPa

  • Pump stops at approximately –60 kPa


Therefore:

Vacuum decreases → Pump starts

↓

Vacuum increases → Pump continues operating

↓

Required vacuum reached → Pump stops


The actual set points must always be checked against the manufacturer's manual because they can vary between systems.


What Happens During Sewage Discharge?

The ejector pump and motor-operated discharge valve are used for the discharge operation.


The discharge can be controlled:

  • Manually

  • Automatically by tank level

  • Automatically by timer


In automatic level control, the high- and low-level switches determine when the discharge operation starts and stops.


How Does Level-Controlled Discharge Work?

When the sewage level rises and activates the high-level switch, the discharge operation begins.

The pump continues transferring sewage until the level falls sufficiently to operate the low-level switch.

The sequence can therefore be remembered as:

High level → Discharge starts

Low level → Discharge stops

This prevents tank overflow while avoiding unnecessary continuous operation of the discharge equipment.


What is the Biological Sewage Treatment Plant?


The biological section is the heart of the STP.


It consists of:

  • Aeration Chamber I

  • Aeration Chamber II

  • Settling Chamber

  • Disinfection Chamber


The complete biological treatment sequence is:

Aeration → Aeration → Settling → Disinfection


What Happens in the Aeration Chambers?


Aeration supplies oxygen required by aerobic microorganisms.

Incoming sewage contains biodegradable organic matter. Microorganisms use this material as a source of energy and carbon while oxygen supports their metabolism.

Air is supplied by an air blower and distributed through air distributors or diffusers.


The aeration process therefore provides:

  • Oxygen

  • Mixing

  • Biological activity

  • Improved breakdown of organic matter


Why are Two Aeration Chambers Used?

The first aeration chamber initiates the biological treatment process.

The wastewater then enters the second aeration chamber, where biological treatment continues.

The two-stage arrangement provides additional biological contact time and allows the microorganisms to continue reducing biodegradable organic matter before the wastewater reaches the settling stage.


What is Activated Sludge?

Activated sludge is a mixture of microorganisms and suspended biological solids formed during the aerobic treatment process.


It contains the microbial population responsible for degrading organic matter.


The microorganisms need:

  • Organic substrate

  • Oxygen

  • Suitable environmental conditions

  • Adequate retention time


A portion of the activated sludge is returned to the aeration chamber to maintain the required biological population.


What is the Function of the Air Blower?

The air blower is one of the most important machines in a biological STP.

Its main function is to supply air to the aeration chambers.

The supplied air provides oxygen to microorganisms and also helps maintain proper mixing of the biological solids.


If aeration is lost for a prolonged period:

  • Dissolved oxygen decreases

  • Aerobic biological activity decreases

  • Treatment efficiency deteriorates

  • Sludge characteristics may change

  • Odour may develop

  • Final effluent quality may deteriorate

Therefore, blower operation should be monitored carefully.


What is the Function of the Settling Chamber?

After biological treatment, the mixed liquor enters the settling chamber.

Here, the activated sludge is separated from the treated water primarily through gravity settling.

The heavier biological solids settle toward the bottom.

The clarified water remains above the settled sludge and flows toward the disinfection chamber.

The settling process is therefore essential for producing clear effluent.


Why is Sludge Returned to the Aeration Chamber?

The sludge contains microorganisms that are required for continued biological treatment.

Therefore, a portion of the settled sludge is returned to the aeration chamber.

In the described arrangement, an air-driven ejector is used for sludge return.


The basic process is:

Settling chamber → Activated sludge → Air ejector → Aeration chamber


This maintains an adequate biological population in the treatment system.


What Happens in the Disinfection Chamber?

The clarified water leaving the settling chamber may still contain microorganisms that must be reduced before discharge.

It therefore enters the disinfection chamber.


Depending on the STP design, disinfection may be achieved using:

  • Chlorine-based chemicals

  • Ultraviolet radiation

  • Other approved technologies


In the system described in the supplied LER3D material, a chlorine-based disinfectant is introduced using a dosing pump.


How Does Chlorine Disinfection Work?


The dosing pump injects disinfectant into the clarified water to reduce harmful microorganisms, including coliform bacteria.

Correct dosage is important.

Under-dosing can result in inadequate disinfection.

Over-dosing can result in excessive chemical consumption and may affect effluent characteristics.

The chemical concentration and dosing rate should always be maintained according to the approved system and manufacturer's instructions.


Can UV be Used Instead of Chlorine?

Yes.

Some marine STPs use UV disinfection.

UV radiation damages the genetic material of microorganisms, preventing them from reproducing effectively.

The advantage is that UV treatment does not require conventional chlorine dosing.


However, UV performance depends on factors such as:

  • Water clarity

  • Suspended solids

  • UV intensity

  • Lamp condition

  • Quartz-sleeve cleanliness

Therefore, a UV system also requires proper maintenance.


What Happens to the Treated Effluent?

After disinfection, the treated effluent is transferred by the discharge pump.

Depending on the vessel's approved arrangement and applicable regulations, it can be:

  • Discharged overboard where permitted

  • Retained onboard

  • Transferred to a shore reception facility

The discharge must comply with MARPOL Annex IV, flag-state requirements, coastal-state requirements, port regulations and the vessel's SMS.


What happens to the sludge produced by the STP?

Biological treatment produces sludge.

Part of it is returned to the aeration chamber to maintain the biological population.

Excess or mineralized sludge must be managed according to the approved shipboard arrangement. It may be transferred to:

  • A sludge holding tank

  • Shore reception facilities

  • Another approved disposal arrangement

The actual disposal route must be based on the vessel's approved system and applicable regulations.


What is MARPOL Annex IV?

MARPOL Annex IV is the section of MARPOL dealing specifically with prevention of pollution by sewage from ships.

It covers:

  • Sewage discharge requirements

  • Sewage treatment equipment

  • Holding arrangements

  • Port reception facilities

  • Surveys

  • Certification

The current IMO framework requires ships within the scope of Annex IV to have an approved sewage treatment plant, approved comminuting and disinfecting system, or sewage holding tank, as applicable.


What are the Sewage Discharge Requirements?

No.

MARPOL Annex IV places restrictions on sewage discharge.

According to the IMO, untreated sewage may generally be discharged only when the applicable conditions are met, including the ship being en route and being more than 12 nautical miles from the nearest land, with the applicable requirements for discharge rate and ship speed. Comminuted and disinfected sewage has different requirements, including a distance of more than 3 nautical miles under the specified conditions.

An approved STP provides a separate regulatory route for discharge, but the ship must use an approved system and comply with applicable operational and local requirements.

Never treat a generic distance figure as permission to discharge in every location. Port, coastal-state, flag-state and Special Area restrictions may apply.


What is MEPC.227(64)?

IMO Resolution MEPC.227(64) contains the 2012 Guidelines on Implementation of Effluent Standards and Performance Tests for Sewage Treatment Plants.

The guidelines address the design, installation, performance and testing of sewage treatment plants required under MARPOL Annex IV.

The guidelines provide a standardized framework for evaluating the performance of approved sewage treatment plants.

They also require appropriate familiarization of ship personnel and emphasize that routine and repair maintenance should be defined by the manufacturer and recorded.


What Effluent Parameters are Important?

Important parameters include:

  • Biochemical Oxygen Demand

  • Chemical Oxygen Demand

  • Suspended solids

  • Thermotolerant coliform bacteria

  • pH

  • Where applicable, nitrogen and phosphorus

The MEPC.227(64) guidelines establish effluent standards for approved plants.

For passenger ships intending to discharge treated sewage in the Baltic Sea Special Area, additional nitrogen and phosphorus removal requirements apply.


What is the Baltic Sea Special Area Requirement?


The Baltic Sea is currently the only Special Area designated under MARPOL Annex IV.

Passenger ships operating in the Special Area are subject to stricter sewage discharge requirements. An approved sewage treatment plant must meet the applicable requirements, including additional nutrient-removal standards where required.

This is particularly important because nitrogen and phosphorus can contribute to eutrophication in sensitive marine environments.


What Parameters Should a Marine Engineer Monitor?

A marine engineer should regularly monitor:

Vacuum

Ensures proper operation of vacuum toilets and sewage piping.

Tank Level

Confirms correct collection and discharge operation.

Blower Operation

Ensures continuous oxygen supply.

Air Supply

Indicates whether adequate aeration is available.

Sludge Condition

Provides an indication of biological and settling performance.

Chemical Dosing

Ensures adequate disinfection.

Pump Performance

Abnormal pressure, current, noise or vibration can indicate developing faults.

Effluent Appearance

Cloudy, excessively coloured or abnormal effluent can indicate treatment problems.


What are the Common Causes of Low Vacuum?

Possible causes include:

  • Leakage in vacuum piping

  • Faulty toilet valve

  • Ejector problem

  • Ejector pump problem

  • Insufficient motive water

  • Faulty vacuum switch

  • Damaged piping

  • Incorrect valve position

A systematic approach should begin with checking the vacuum gauge, pump operation, valve positions and visible leakage before dismantling equipment.


Why Does an STP Produce Bad Odour?

A healthy aerobic biological process should not normally produce severe foul odours.

Possible causes include:

  • Insufficient aeration

  • Blower failure

  • Excessive sludge accumulation

  • Anaerobic conditions

  • Excessive retention time

  • Biological imbalance

  • Poor ventilation

The first engineering checks should include blower operation, air supply, sludge condition and tank condition.


What Causes Poor Effluent Quality?

Poor effluent quality can result from:

  • Insufficient aeration

  • Low biological activity

  • Excessive hydraulic loading

  • Excessive sludge

  • Poor settling

  • Sludge carryover

  • Chemical dosing failure

  • UV system failure

  • Incorrect sludge return

  • Excessive cleaning chemicals entering the plant

The engineer should determine whether the problem originates in the biological stage, settling stage, disinfection stage or discharge system.


What Causes Excessive Foaming?

Foaming can occur because of:

  • Changes in wastewater composition

  • Surfactants

  • Biological imbalance

  • Excessive biological growth

  • Aeration conditions

  • Sludge problems

The correct approach is to identify and eliminate the underlying cause rather than simply attempting to remove the foam.


What Happens if the STP is Left Without Aeration?

Without sufficient oxygen, aerobic microorganisms cannot maintain normal biological activity.

The result can be:

Blower failure → Reduced oxygen → Reduced biological activity → Poor treatment → Poor effluent quality

If the plant remains without aeration for an extended period, the biological condition may deteriorate significantly.

The manufacturer's instructions should be followed when restoring a plant after prolonged shutdown.


What are the Important STP Maintenance Activities?

Routine maintenance should include inspection and testing of:

  • Air blower

  • Air filters

  • Air diffusers

  • Pumps

  • Ejectors

  • Vacuum switch

  • Level switches

  • Motor-operated valves

  • Chemical dosing pump

  • UV system where fitted

  • Control panel

  • Alarm system

  • Pipes and valves

  • Sludge system

IMO's MEPC.227(64) guidelines specifically emphasize that routine maintenance should be defined by the manufacturer and that maintenance and repair activities should be recorded.


What Daily Checks Should an Engineer Carry Out?

A practical daily inspection can include:

  • Check vacuum level

  • Check sewage tank level

  • Check blower operation

  • Check air distribution

  • Check pump operation

  • Check chemical level

  • Check dosing pump

  • Check alarms

  • Check for leakage

  • Observe effluent condition

  • Check abnormal noise and vibration

  • Verify that automatic sequences are functioning correctly

These checks should be incorporated into the vessel's PMS and operating procedures.


What Safety Precautions are Required?

Sewage systems present both biological and mechanical hazards.

Appropriate PPE should be used when working around sewage equipment.

Particular care is required when handling disinfecting chemicals.

Most importantly, sewage tanks and treatment chambers can constitute enclosed spaces.

Potential hazards include:

  • Oxygen deficiency

  • Hydrogen sulphide

  • Methane

  • Other toxic gases

  • Engulfment

  • Slipping hazards


Can an engineer enter a sewage tank simply because it appears empty?

Answer: No.

An apparently empty sewage tank can still contain a hazardous atmosphere.

Entry must only take place under the vessel's approved enclosed-space entry procedure, including atmosphere testing, ventilation, communication, standby arrangements and other required controls.


Why is Hydrogen Sulphide Dangerous?


Hydrogen sulphide can be generated when organic material undergoes anaerobic decomposition.

It is highly toxic and can rapidly impair the sense of smell, meaning that smell cannot be relied upon as a warning method.

Therefore, atmosphere testing is essential before entering sewage tanks or other potentially hazardous enclosed spaces.


What Happens if the Sewage Treatment Plant Fails?

The response depends on the vessel's approved sewage arrangement, but generally the crew should:

  • Stop unauthorized sewage discharge

  • Isolate the defective equipment where necessary

  • Use the approved alternative sewage arrangement

  • Retain sewage in the designated holding system where available

  • Inform the responsible engineer/officer

  • Carry out troubleshooting and repair

  • Record the failure and corrective action

  • Follow company SMS and reporting requirements

The vessel must not simply bypass the treatment system and discharge sewage without confirming that such discharge is legally permitted.


How is a Marine STP Different from a Conventional Gravity Sewage System?

A vacuum sewage system uses pressure differential to transport sewage.

A conventional gravity system relies primarily on gravitational flow.

Parameter

Vacuum System

Gravity System

Sewage transport

Vacuum/pressure differential

Gravity

Flush water

Generally low

Generally higher

Pipe size

Generally smaller

Generally larger

Routing flexibility

High

More dependent on gravity

Vacuum equipment

Required

Not normally required

Suitability onboard

Very useful

Also used depending on design

The exact arrangement depends on the ship's design.


How Should the STP be Operated During Port Stay?

No.

Port and coastal regulations can impose restrictions beyond the general MARPOL framework.

During port stay, sewage may need to be:

  • Retained onboard

  • Stored in a holding tank

  • Delivered to a shore reception facility

  • Treated and discharged only when specifically permitted

The vessel's SMS, port requirements, flag-state requirements and local environmental regulations must always be consulted.


Important Oral Examination Questions

What is the purpose of an STP?

To treat ship-generated sewage so that the resulting effluent meets the applicable environmental and regulatory requirements before permitted discharge.

What is the principle of biological sewage treatment?

Aerobic microorganisms consume biodegradable organic matter in the presence of oxygen.

What are the main chambers of the described biological STP?

Two aeration chambers, one settling chamber and one disinfection chamber.

What is the function of the aeration chambers?

To supply oxygen and provide conditions for aerobic biological treatment.

Why is activated sludge returned?

To maintain an adequate population of microorganisms in the biological treatment process.

What is the function of the settling chamber?

To separate activated sludge from clarified treated water.

What is the function of the disinfection chamber?

To reduce harmful microorganisms in the clarified effluent before permitted discharge.

What is used for chemical disinfection?

A disinfectant may be injected using a dosing pump; chlorine-based systems are one common arrangement.

Can UV be used?

Yes, depending on the approved STP design.

What controls the vacuum pump?

A vacuum/pressure switch according to the system's preset vacuum levels.

What starts level-controlled discharge?

The high-level switch.

What stops level-controlled discharge?

The low-level switch.

What is MARPOL Annex IV?

The MARPOL annex dealing with prevention of pollution by sewage from ships.

What is MEPC.227(64)?

The IMO 2012 guidelines covering effluent standards and performance testing for sewage treatment plants.

What is the most important factor for aerobic biological treatment?

Adequate oxygen supply and healthy biological activity.

What happens if the blower fails?

Aeration decreases, biological activity deteriorates and treatment performance can fall.

Why is sludge recirculated?

To maintain the required concentration of active microorganisms in the biological treatment process.

Why is sewage tank entry dangerous?

Because the tank can contain toxic gases, oxygen-deficient atmospheres and other enclosed-space hazards.